ARCHITECTS
Specifications
GERARD TILE
Dimensions
Panel Width: 15.5” (393.7 mm) (39.37 cm)
Panel Length: 45.75” (1162.05 mm) (116.205 cm)
Pcs/ Square: 22.6
Weight/ Sq. Ft: 1.32 lbs (0.599 kg)
Weight/ per panel 5.83 lbs (2.64 kg)
Packaging
Each pallet contains 340 tiles (15 squares of material)
Pallet weight is 2,150 lbs (975 kg)
Installation
Open Rafter
Solid Sheathing
Batten mounted 2x2 wood or metal battens
Can re-roof over existing asphalt shingles*
Can re-roof over existing wood shake shingles*
Minimum Roof Slope: 2.5 : 12
Maximum Roof Slope: 12 : 12 or full vertical face
Substrate
26 gauge Galvalume®
Testings
UL- 790 Fire
UL-1897 Uplift
UL-580 Wind Uplift
UL-2218 Impact
Warranty
Transferable Limited Lifetime Warranty
Reports
City of LA Report
ICC ESR
Miami Dade County, FL NOA
Texas Department of Insurance
Extra
May reduce insurance premiums
May qualify for energy savings, rebates and or credits
* Check with local building code requirements
CANYON SHAKE
Dimensions
Panel Width: 16.5” (419.1 mm) (41.91 cm)
Panel Length: 45” (1143 mm) (114.3 cm)
Pcs/ Square: 22.6
Weight/ Sq.Ft: 1.32 lbs (0.599 kg)
Weight/ per panel: 5.83 lbs (2.64 kg)
Packaging
Each pallet contains 340 tiles (15 squares of material)
Pallet weight is 2,150 lbs (975 kg)
Installation
Open Rafter
Solid Sheathing
Batten mounted 2x2 wood or metal battens
Can be installed direct to deck (battenless)
Can re-roof over existing asphalt shingles*
Can re-roof over existing wood shake shingles*
Minimum Roof Slope: 3 : 12
Maximum Roof Slope: 12 : 12 or full vertical face
Substrate
26 gauge Galvalume®
Testings
UL- 790 Fire
UL-580 Wind Uplift
UL-2218 Impact
Warranty
Transferable Limited Lifetime Warranty
Reports
City of LA Report
ICC ESR
Miami Dade County, FL NOA
Texas Department of Insurance
Extra
May reduce insurance premiums
May qualify for energy savings, rebates and or credits
* Check with local building code requirements
NB TILE
Dimensions
Panel Width: 17.25” (438.15 mm) (43.815 cm)
Panel Length: 46” (1168.4 mm) (116.84 cm)
Pcs/ Square: 22.6
Weight/ Sq.Ft: 1.5 lbs (0.680 kg)
Installation
Open Rafter
Solid Sheathing
Battenless installation method
Can be batten mounted 2x2 wood or metal battens
Can re-roof over existing asphalt shingles*
Can re-roof over existing wood shake shingles*
Minimum Roof Slope: 2.5 : 12
Maximum Roof Slope: 12 : 12 or full vertical face
Substrate
26 gauge Galvalume®
Testings
UL- 790 Fire
UL-580 Wind Uplift
UL-2218 Impact
Warranty
Transferable Limited Lifetime Warranty
Reports
ICC ESR
Miami Dade County, FL NOA
Texas Department of Insurance
Extra
May reduce insurance premiums
May qualify for energy savings, rebates and or credits
* Check with local building code requirements
GRANITE RIDGE
Dimensions
Panel Width: 15.6” (396.26 mm) (39.62 cm)
Panel Length: 46.2” (1173.48 mm) (117.348 cm)
Pcs/ Square: 24
Weight/ Sq.Ft: 1.2 lbs (0.544 kg)
Installation
Solid Sheathing
Battenless installation method only
Can re-roof over existing asphalt shingles*
Can re-roof over existing wood shake shingles*
Minimum Roof Slope: 4 : 12
Maximum Roof Slope: 12 : 12 or full vertical face
Substrate
26 gauge Zinc Allum
Testings
UL- 790 Fire
UL-1897 Uplift
UL-580 Wind Uplift
UL-2218 Impact
Warranty
Transferable Limited Lifetime Warranty
Reports
ICC ESR
Miami Dade County, FL NOA
Texas Department of Insurance
Extra
May reduce insurance premiums
May qualify for energy savings, rebates and or credits
* Check with local building code requirements
GUARDIAN SHINGLE
Dimensions
Panel Width: 15.6” (396.24 mm) (39.62 cm)
Panel Length: 46.2” (1173.48 mm) (117.348 cm)
Pcs/ Square: 24
Weight/ Sq.Ft: 1.2 lbs (0.544 kg)
Installation
Solid Sheathing
Battenless installation method only
Can re-roof over existing asphalt shingles*
Can re-roof over existing wood shake shingles*
Minimum Roof Slope: 4 : 12
Maximum Roof Slope: 12 : 12 or full vertical face
Substrate
26 gauge Zinc Allum
Testings
UL- 790 Fire
UL-1897 Uplift
UL-580 Wind Uplift
UL-2218 Impact
Warranty
Transferable Limited Lifetime Warranty
Reports
Texas Department of Insurance
Extra
May reduce insurance premiums
May qualify for energy savings, rebates and or credits
* Check with local building code requirements
BARREL VAULT
Dimensions
Panel Width: 16.25” (412.75 mm) (41.275 cm)
Panel Length: 45.5” (1155.7 mm) (115.57 cm)
Pcs/ Square: 24
Weight/ Sq.Ft: 1.5 lbs (0.680 kg)
Installation
Solid Sheathing
Open rafter
Battenless installation
Batten installation on 2x2 wood or metal battens
Can re-roof over existing asphalt shingles*
Can re-roof over existing wood shake shingles*
Minimum Roof Slope: 2:5 : 12
Maximum Roof Slope: 12 : 12 or full vertical face
Substrate
26 gauge Galvalume®
Testings
UL- 790 Fire
UL-1897 Uplift
UL-580 Wind Uplift
UL-2218 Impact
Warranty
Transferable Limited Lifetime Warranty
Reports
Texas Department of Insurance
ICC ESR
Miami Dade County, FL NOA
Extra
May reduce insurance premiums
May qualify for energy savings, rebates and or credits
* Check with local building code requirements
MISSION TRIM & SHAKE CAPS
For ridge, Rake and Hip areas
Dimensions
Size is 15.5” x 6” (393.7 x 152.4 mm) (39.37 x 15.24 cm)
Packaging
1 pallet contains 16 boxes (800 pcs)
Weight per pallet is 1,045 lbs (474 kg)
Pallet size 42”x 54” (1066.8 x 1371.6 mm) (106.68 x 137.16 cm)
Each trim box contains 50 pcs of trim, 3 end discs and 1 touch up kit
|